Pediatric pneumonia detection (chest X-ray)
imagingLeaderboard
ROC-AUC (zero-shot)
ROC-AUC on the 624 official test radiographs (atlas-full-v1; 100 in atlas-n100-v1) of a model's own pneumonia score (a native classifier's probability, or the image-text similarity margin between a pneumonia and a normal prompt), with no training here.
Best in the catalogue: 0.909 (the best visible result here, not a state of the art). Ranks are the server's: ties share a rank. A ≠ marks a row whose n differs from the board's usual n (624). Floors are trivial baselines scored on the same items, shown unranked.
| # | Model | Value | 95% CI | n | Source | Overlap |
|---|---|---|---|---|---|---|
| 1 | bio-nlp/biomedclip-pubmedbert-256-vit-base-patch16-224 | 0.909 best | [0.886, 0.931] | 624 | reproduced | unknown |
| 2 | medical-imaging/vit-chest-xray | 0.717 | [0.679, 0.754] | 624 | reproduced | none declared |
Secondary metrics (4) · zero-shot · context, not ranked
Accuracy (zero-shot)
Share of the 624 test radiographs (atlas-full-v1; 100 in atlas-n100-v1) whose label is the model's own decision (a classifier's probability above 0.5, or a positive pneumonia-minus-normal prompt margin).
| Model | Value | 95% CI | n | Source | Overlap |
|---|---|---|---|---|---|
| bio-nlp/biomedclip-pubmedbert-256-vit-base-patch16-224 | 0.619 best | [0.590, 0.649] | 624 | reproduced | unknown |
| medical-imaging/vit-chest-xray | 0.375 | [0.375, 0.375] | 624 | reproduced | none declared |
Sensitivity, pneumonia (zero-shot)
Share of the pneumonia radiographs called pneumonia by the model's own decision (a classifier's probability above 0.5, or a positive pneumonia-minus-normal prompt margin) (pos_label 1).
| Model | Value | 95% CI | n | Source | Overlap |
|---|---|---|---|---|---|
| bio-nlp/biomedclip-pubmedbert-256-vit-base-patch16-224 | 0.390 best | [0.344, 0.438] | 624 | reproduced | unknown |
| medical-imaging/vit-chest-xray | 0.000 | [0.000, 0.000] | 624 | reproduced | none declared |
Specificity, pneumonia (zero-shot)
Share of the normal radiographs called normal by the model's own decision (a classifier's probability above 0.5, or a positive pneumonia-minus-normal prompt margin) (pos_label 1).
| Model | Value | 95% CI | n | Source | Overlap |
|---|---|---|---|---|---|
| bio-nlp/biomedclip-pubmedbert-256-vit-base-patch16-224 | 1.000 best | [1.000, 1.000] | 624 | reproduced | unknown |
| medical-imaging/vit-chest-xray | 1.000 best | [1.000, 1.000] | 624 | reproduced | none declared |
Average precision (zero-shot)
Average precision (area under the precision-recall curve) of the same zero-shot pneumonia score, pneumonia as the positive class.
| Model | Value | 95% CI | n | Source | Overlap |
|---|---|---|---|---|---|
| bio-nlp/biomedclip-pubmedbert-256-vit-base-patch16-224 | 0.953 best | [0.940, 0.964] | 624 | reproduced | unknown |
| medical-imaging/vit-chest-xray | 0.834 | [0.808, 0.858] | 624 | reproduced | none declared |
Protocol
What is measured. Whether a pediatric chest radiograph shows
pneumonia (bacterial or viral) or is normal. Data: Kermany et al.,
Cell 2018 (Mendeley Data doi:10.17632/rscbjbr9sj.2), anterior-posterior
radiographs of children aged one to five from Guangzhou Women and
Children's Medical Center, graded by two expert physicians (the test set
checked by a third), as mirrored by hf-vision/chest-xray-pneumonia
(JPEG, sizes vary around 1,000-2,000 pixels).
Split. The official test split (624 images: 234 normal, 390
pneumonia) is the test pool and the official training split (5,216:
1,341 / 3,875) the train pool; the 16-image validation split is not
used. atlas-full-v1 tests on the whole official test split (624
images); atlas-n100-v1 drew 100 test images stratified by label. Both
draw 500 train images stratified by label (largest-remainder quotas,
seed-hash rank). Training images whose patient number (person123 in
person123_bacteria_456.jpeg, IM-0115 in IM-0115-0001.jpeg) also
appears among the test images are excluded from training, so the two
versions' train sets differ slightly (461 of 500 shared; 359 pneumonia /
141 normal in atlas-full-v1). The source numbers patients per folder,
so a shared number may not be the same child; dropping it is the
conservative choice.
Test size. The leaderboard version is atlas-full-v1 on every
profile: the whole official test split, 624 images, the set the
literature reports on (an image model scores 624 radiographs in about a
minute). The earlier atlas-n100-v1 stays frozen and its cells stay
current; it is a separate ranking, never mixed with the full one.
Zero-shot (roc_auc_zero_shot). Either a native pneumonia
classifier's probability, or, for image-text models, the similarity of
the image to "a chest x-ray showing pneumonia" minus its similarity to
"a normal chest x-ray". Nothing is trained here.
Probe (roc_auc_probe). Frozen pooled image embeddings; a logistic
head is fit on the 500 training images and scores every test image.
Uncertainty. 95 % bootstrap interval over test images, 1,000 resamples stratified by label.
Caveats. Pneumonia images outnumber normal ones about 3 to 1; ROC-AUC is insensitive to that. The dataset is widely used to fine-tune public chest X-ray classifiers (several keremberke/YOLOv8 classification checkpoints on the hub were trained on a derivative of it), so their zero-shot numbers may include training images: a known overlap, reported with the results. Adult chest X-ray models face a domain shift (children, AP views).
Accuracy, sensitivity, specificity, average precision
(accuracy_zero_shot, accuracy_probe, sensitivity_zero_shot,
sensitivity_probe, specificity_zero_shot, specificity_probe,
average_precision_zero_shot, average_precision_probe; metrics review).
Kermany et al. report accuracy, sensitivity and specificity next to
ROC-AUC. They read each model's own decision: a classifier's or the
probe's probability above 0.5, or a positive prompt margin for an
image-text model, pneumonia as the positive class; no threshold is tuned
here, so a model whose scores are not calibrated to that cut can score a
low sensitivity or specificity with a high ROC-AUC. Always answering
pneumonia gives accuracy 0.625 (390 / 624) and specificity 0. Average
precision is threshold-free, like ROC-AUC.
Data
pneumonia: hf_datasethf-vision/chest-xray-pneumoniaat revisionc1a67c18df1a52ec332ffc00418f4eaa61a9f2bc, licence cc-by-4.0, catalogued asmedical-imaging/chest-xray-pneumonia
Subset
- seed 20261006
- test: 100 item(s), stratified by label
- train: 500 item(s), stratified by label, disjoint by patient_number
- leaderboard version
atlas-full-v1on every profile: the whole eligible test pool (the sizes above define the n version) - results at
atlas-full-v1use subset3ae07456bf0152dc - results at
atlas-n100-v1use subset09b1f320caf781e4
Metrics
roc_auc_zero_shot— ROC-AUC (zero-shot); protocol zero_shot; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelroc_auc_probe— ROC-AUC (logistic probe); protocol probe; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelaccuracy_zero_shot— Accuracy (zero-shot); protocol zero_shot; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelsensitivity_zero_shot— Sensitivity, pneumonia (zero-shot); protocol zero_shot; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelspecificity_zero_shot— Specificity, pneumonia (zero-shot); protocol zero_shot; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelaverage_precision_zero_shot— Average precision (zero-shot); protocol zero_shot; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelaccuracy_probe— Accuracy (logistic probe); protocol probe; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelsensitivity_probe— Sensitivity, pneumonia (logistic probe); protocol probe; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelspecificity_probe— Specificity, pneumonia (logistic probe); protocol probe; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by labelaverage_precision_probe— Average precision (logistic probe); protocol probe; higher is better; range [0.0, 1.0]; 95% bootstrap CI, 1000 resamples, stratified by label
Sample
The leaderboard (atlas-full-v1) scores the 624 official test
radiographs (100 in atlas-n100-v1). Three test radiographs (input: the
JPEG; expected output: a score that ranks pneumonia above normal):
| item_id | label |
|---|---|
pneumonia-test-person136_bacteria_648 | 1 (PNEUMONIA, bacterial) |
pneumonia-test-person51_virus_105 | 1 (PNEUMONIA, viral) |
pneumonia-test-NORMAL2-IM-0246-0001 | 0 (NORMAL) |